1.0 Specifications
•
Input Power
: 9 to 15 VDC; 15 mA @ 12 VDC.
•
Standby Power
: There is no internal standby battery. Connect to
DC power sources capable of supplying standby power if primary
power fails. Fifteen mA-H required for each hour of standby time
needed.
Four hours (60 mA-H) minimum are required for
Underwriters Laboratories' Certificated installations.
•
Coverage
:
Standard Broad
35 ft. by 35 ft.
(10.7 m by 10.7 m)
Barrier (Optional)
35 ft. by 10 ft.
(10.7 m by 3.1 m)
Long Range (Optional)
70 ft. by 10 ft.
(21.4 m by 3.1 m)
Pet Alley (Optional)
35 ft. by 35 ft.
(10.7 m by 10.7 m)
with 70 ft. (21.4 m) Long Range
•
Sensitivity
: Standard or Intermediate.
•
Built in Poppit for use with Radionics Bosch ZONEX
•
Tamper Switch
: Normally Closed (with cover in place) tamper
switch. Contacts rated at 3 watts, 28 VDC, 125 mA maximum.
•
Temperature
: The storage and operating range is -40
°
to +120
°
F
(-40
°
to +49
°
C).
For U. L. Certificated installations, the range is
+32
°
to +120
°
F (0
°
to +49
°
C).
•
Options
: B335-3* Low Profile Swivel Mount Bracket, OMB93-3*
Barrier Mirror, OMLR93-3* Long Range Mirror, and the OMP93-3*
Pet Alley Mirror. *Shipped in packages of three.
Note:
Misalignment of the detector when using an optional
mounting bracket may reduce range.
Código de producto: D9135T